i.safe MOBILE · Dedicated Ex tablet

i.safe MOBILE IS930.1

  • Zone 1/21
  • ATEX
  • IECEx
  • UKEX
  • IIC
  • T4
  • Class I Division 1

The i.safe MOBILE IS930.1 is an intrinsically safe (Ex ib) 8-inch Android tablet from i.safe MOBILE, certified for Zone 1/21 under ATEX, IECEx and UKEX. It runs Android 14.

Certified for
Zone 1/21
Protection
Intrinsic safety (Ex ib)
Screen
8-inch
Temperature class
T4 (≤ 135 °C)
Ambient temperature
−20 °C to +60 °C
Operating system
Android 14
Security updates
Until Q1 2027
Weight
890 g
Price
On request
Request a price
See how it compares to alternatives

Overview

Strengths and limitations

Strengths

  • ATEX, IECEx and UKEX certified, with published certificate numbers
  • Also certified for Class I Division 1 in North America
  • A mining version (Group I) is also available
  • Camera-free version available for sites that restrict cameras
  • Among the lightest Zone 1 tablets of its size we list, at 890 g in use

Limitations

  • T4 temperature class: fine for most gases, but not those that ignite below 135 °C
  • Security updates end in Q1 2027
  • Battery isn't user-replaceable
  • Not certified for Zone 0

Certification

Where you can use it

Gas

  • Zone 0not certified.Explosive gas present continuously or for long periods
  • Zone 1certified.Explosive gas likely in normal operation
  • Zone 2certified.Explosive gas unlikely, and only briefly

Dust

  • Zone 20not certified.Combustible dust present continuously or for long periods
  • Zone 21certified.Combustible dust likely in normal operation
  • Zone 22certified.Combustible dust unlikely, and only briefly

The Ex marking, decoded

ATEXCertificate EPS 19 ATEX 1 071 X

Gas atmospheresZones 1 and 2

II2GExibIICT4Gb

II Equipment group
Group II: equipment for surface industries (not mining).
2G ATEX category
Category 2 for gas: suitable down to Zone 1.
Ex Explosion protected
Certified to the IEC 60079 / EN 60079 series.
ib Protection type
Intrinsic safety, level "ib": stays safe with one fault. Suitable for Zone 1 and 2.
IIC Gas group
Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4 Temperature class
Surface stays below 135 °C. T6 is the strictest class.
Gb Protection level
Equipment protection level Gb (high): suitable for Zone 1 and 2.

Dust atmospheresZones 21 and 22

II2DExibIIICT135°CDbIP6X

2D ATEX category
Category 2 for dust: suitable down to Zone 21.
IIIC Dust group
Dust group IIIC: conductive dust. The most demanding group; also covers IIIA and IIIB.
T135°C Max surface temperature
Surface stays below 135°C in dust.
Db Protection level
Equipment protection level Db (high): suitable for Zone 21 and 22.
IP6X Ingress protection
Dust-tight; no water rating stated.

IIExib as above.

Versions

  • IS930.M1

    Mining version, also certified for Group I (underground mining).

    Marking
    ATEX: I M1 Ex ia I Ma IP64 | IECEx: Ex ia I Ma IP64
    Certificates
    EPS 19 ATEX 1 128 X; IECEx EPS 19.0063X

Safe use

Rules for the hazardous area

Ambient temperature (Ta)
−20 °C to +60 °C
Charging
Outside the hazardous area only
Battery swap
Outside the hazardous area only
Ports and accessories in the zone
Opening any interface or connector cover in an Ex area is not permitted. Wired data connection and charging only outside Ex areas (docking station IS-DS930.1, i.safe PROTECTOR cables). A commercial microSD card may be used in its slot in the Ex area (IECEx text).
Certified accessories
Maker page lists: IS-DS930.1 docking station set (RJ45, 3 x USB), IS-MC930.1 six-bay multi charger, i.safe PROTECTOR 2.0 / 3.0 USB-C cables, leather case with shoulder/belt/carry straps, vehicle mount. Charging and cable accessories are for use outside Ex areas. Which accessories are Ex-rated for use inside Ex areas is not stated for IS930.1.Unconfirmed, see note 1
IP code in the Ex certificate
IP6X (dust marking)
Operating temperature
−20 °C to +60 °C

Conditions of use

IECEx X conditions: battery may be charged outside explosion hazardous areas only; protect against permanent UV light and high electrostatic charge processes; permitted ambient temperature −20 °C to +60 °C. Safety instructions: all interface covers closed in Ex areas; charging only outside Ex areas (+5 to +35 °C); battery not interchangeable.

Specifications

Full specifications

Certification

ATEX marking
II 2G Ex ib IIC T4 Gb / II 2D Ex ib IIIC T135°C Db IP6X
ATEX certificate
EPS 19 ATEX 1 071 X
IECEx marking
Ex ib IIC T4 Gb / Ex ib IIIC T135°C Db IP6X
IECEx certificate
IECEx EPS 19.0034X (Issue 0, 2019-12-20)
UKEX certificate
CML 21UKEX2490X
Other approvals
EAC, KCs (Korea), INMETRO (Brazil), Japan-Ex, IA (South Africa), PESO (India), TELEC
North America
NEC 500: Class I Div 1 Groups A, B, C, D T4; Class II Div 1 Groups E, F, G T135°C; Class III Div 1
Protection level (EPL)
Gb / Db
Dust group
IIIC
Max surface temperature (dust)
135 °C

Device

Type
Dedicated Ex tablet
Part numbers
Model M93A01 (DoC); article numbers not published on maker page
Operating system
Android 14
Edition
Android 14
OS at launch
Android 9Unconfirmed, see note 3
Security updates
Until Q1 2027
Processor
Qualcomm Snapdragon SDM660 octa-core
Processor architecture
Arm
Memory (RAM)
4 GB
Storage
64 GB, microSD up to 512 GB

Field capabilities

Push-to-talk
Via app (PTT/PoC app on a programmable key; no PTT button accessory listed for IS930)
Emergency / SOS
Built in (dedicated red SOS key)
Lone worker
Via app (LWP ready: third-party application required, per maker page)
Barcode scanning
Via app (camera-based; no dedicated scan engine listed)
NFC reading
Built in (NFC)
3D scanning / LiDAR
Not possible (no depth sensor listed)
Remote expert / video calls
Via app (front and rear cameras, Wi-Fi/LTE; third-party app)
Windows desktop software
Not possible (Android)

Display and camera

Display
8-inch Glove-usable touch display; Corning Gorilla Glass V3 stated on the IS930.M1 page (not on the IS930.1 page)
Touch
Usable with gloves (maker); wet-touch not stated
Rear camera
13 MP autofocus
Front camera
5 MP fixed focus

Connectivity

Network
4G LTE (no 5G)
Wi-Fi
Wi-Fi 5 (802.11 a/b/g/n/ac/e/k/r/h) with hotspot
Bluetooth
Bluetooth 5
NFC
Yes
Satellite positioning
GPS, A-GPS, Glonass, Beidou (Galileo added on IS930.M1 page)
SIM
Micro-SIM

Physical and power

Weight
890 g
Dimensions
237 × 156 × 22 mm
Ingress protection
IP68
Ruggedness
MIL-STD-810H
Battery energy
30.2Unconfirmed, see note 4
Hot-swap battery
NoUnconfirmed, see note 3
Replaceable battery
No
Ports and expansion
USB-C; 24-pin docking interface; magnetic charger port; earphone jack; microSD slot; micro-SIM
Docking
Office dock IS-DS930.1 (RJ45, 3 x USB); IS-MC930.1 six-bay multi charger; vehicle mount
Keyboard
No (slate)

Controls & Accessibility

Keys
SOS key (red); two freely programmable keys
Push-to-talk key
No
Glove touch
Yes

Fleet and support

Manufacturer
i.safe MOBILE GmbH, Germany

Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the i.safe MOBILE GmbH website for the full data sheet.

Compare

How it compares

Best in this comparison

i.safe MOBILE IS930.1 compared with its closest alternatives
i.safe MOBILEi.safe MOBILE IS930.1This tablet
ecom (Pepperl+Fuchs)ecom Tab-Ex 05 DZ1Full comparison: i.safe MOBILE IS930.1 vs ecom Tab-Ex 05 DZ1
TypeDedicated Ex tabletDedicated Ex tabletConverted tabletDedicated Ex tablet
Screen size8-inch8-inch8-inch10.1-inch
AvailabilityCurrentCurrentCurrentCurrent
Gas zonesZone 1, Zone 2Zone 1, Zone 2Zone 1, Zone 2Zone 0, Zone 1, Zone 2 (best in this comparison)
Dust zonesZone 21, Zone 22Zone 21, Zone 22Zone 21, Zone 22Zone 20, Zone 21, Zone 22
ProtectionIntrinsic safety (Ex ib)Flameproof enclosure (Ex db) with an intrinsically safe circuit (Ex ia)Flameproof enclosure (Ex db)Intrinsic safety (Ex ia)
Gas groupIICIICIICIIC
Temperature classT4T6 (best in this comparison)T6 (best in this comparison)T4
CertificationATEX + IECEx + UKEXATEX + IECExATEX + IECExATEX + IECEx
North AmericaClass I Division 1Class I Division 1—Class I Division 1
Ambient temperature−20 °C to +60 °C−20 °C to +55 °C−20 °C to +50 °C−20 °C to +55 °C
Charging in the Ex areaNot allowedNot allowedNot allowedNot allowed
Operating systemAndroid 14Android 16Android 16Windows 11 IoT Enterprise
Security updatesUntil Q1 2027Until Q1 2032Until January 2029Until October 2034 (best in this comparison)
Weight890 g (best in this comparison)1122 g940 g1430 g
Display8-inch Glove-usable touch display; Corning Gorilla Glass V3 stated on the IS930.M1 page (not on the IS930.1 page)8-inch TFT, capacitive multitouch, 60 Hz / adaptive up to 120 Hz; Corning Gorilla Glass 3 (DZ1/DZ2), Gorilla Glass 5 (D2)8-inch TFT LCD, 120 Hz adaptive; Corning Gorilla Glass 510.1-inch AHVA (IPS-type), 1000:1 contrast, 170 degree viewing angle
5GNoYesYesNo
Pen / stylus—Samsung S Pen included (pressure sensitive), with Tab-Ex S Pen holderS Pen supported (IP68 S Pen in the box on the UK page)Stylus supplied (type not stated)
Replaceable batteryNoNo—No
Hot-swap batteryNo———
PriceOn requestOn requestOn requestOn request

FAQ

Common questions

Is the i.safe MOBILE IS930.1 certified for Zone 1?

Yes. The i.safe MOBILE IS930.1 is certified for Zone 1/21 with the marking II 2G Ex ib IIC T4 Gb. Equipment certified for Zone 1 can also be used in Zone 2.

Can the i.safe MOBILE IS930.1 be used in Zone 0?

No. It is not certified for Zone 0. Zone 0 needs equipment with protection level Ga, such as Ex ia intrinsic safety.

What type of explosion protection does the i.safe MOBILE IS930.1 use?

It is intrinsically safe: intrinsic safety (Ex ib). Intrinsic safety limits the electrical and thermal energy in the device below the level that could ignite the surrounding atmosphere.

What does T4 mean for the i.safe MOBILE IS930.1?

Its surface stays below 135 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.

Can you charge the i.safe MOBILE IS930.1 in a hazardous area?

No. The certificate only allows charging outside the hazardous area.

Which ports and accessories can be used with the i.safe MOBILE IS930.1 in the hazardous area?

Opening any interface or connector cover in an Ex area is not permitted. Wired data connection and charging only outside Ex areas (docking station IS-DS930.1, i.safe PROTECTOR cables). A commercial microSD card may be used in its slot in the Ex area (IECEx text).

What operating system does the i.safe MOBILE IS930.1 run?

Android 14. Security updates until Q1 2027.

How much does the i.safe MOBILE IS930.1 cost?

Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.

Notes on unconfirmed values

  1. Not checked against the certificate for this exact model.
  2. Approximate: the maker doesn't publish a launch date. Based on the certificate date or the maker's announcement.
  3. From a single or secondary source; the maker doesn't state it for this model.
  4. Calculated from the maker's battery capacity and voltage; the maker doesn't state watt-hours.

Sources and verification

Facts last verified on against:

Always check the certificate for your exact model before use. Spotted an error? Tell us.