Getac T800-Ex, front view

Getac · Rugged tablet, Ex version

Getac T800-Ex

  • Discontinued
  • Zone 2/22
  • IECEx
  • IIC
  • T4

Discontinued. No longer in Getac's range; no end-of-sale notice.

The Getac T800-Ex is the hazardous-area version of a Getac rugged 8.1-inch tablet, certified for Zone 2/22 under IECEx. It is an intrinsically safe (Ex ic) design; its operating system version isn't published. It has been discontinued.

Certified for
Zone 2/22
Protection
Intrinsic safety (Ex ic) with inherently safe optical radiation (op is)
Screen
8.1-inch
Temperature class
T4 (≤ 135 °C)
Ambient temperature
−21 °C to +50 °C
Operating system
Not published
Price
On request
Request a price
See how it compares to alternatives

Overview

Strengths and limitations

Strengths

  • Certified for Zone 2/22

Limitations

  • No longer in the maker's current range
  • Zone 2 only, so not for Zone 1 areas
  • T4 temperature class: fine for most gases, but not those that ignite below 135 °C
  • Dust group IIIB: combustible flyings and non-conductive dust only, not conductive dust
  • In-use weight not published

Certification

Where you can use it

Gas

  • Zone 0not certified.Explosive gas present continuously or for long periods
  • Zone 1not certified.Explosive gas likely in normal operation
  • Zone 2certified.Explosive gas unlikely, and only briefly

Dust

  • Zone 20not certified.Combustible dust present continuously or for long periods
  • Zone 21not certified.Combustible dust likely in normal operation
  • Zone 22certified.Combustible dust unlikely, and only briefly

The Ex marking, decoded

IECExCertificate IECEx EPS 16.0015X

Gas atmospheresZone 2

Exicop isIICT4Gc

Ex Explosion protected
Certified to the IEC 60079 / EN 60079 series.
ic Protection type
Intrinsic safety, level "ic": safe in normal operation. Zone 2 only.
op is Protection type
Inherently safe optical radiation: light from the camera flash or torch is limited below the level that could ignite the atmosphere.
IIC Gas group
Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4 Temperature class
Surface stays below 135 °C. T6 is the strictest class.
Gc Protection level
Equipment protection level Gc (enhanced): suitable for Zone 2.

Dust atmospheresZone 22

Exicop isIIIBT130°CDc

IIIB Dust group
Dust group IIIB: non-conductive dust. Also covers IIIA.
T130°C Max surface temperature
Surface stays below 130°C in dust.
Dc Protection level
Equipment protection level Dc (enhanced): suitable for Zone 22.

Exicop is as above.

Safe use

Rules for the hazardous area

Ambient temperature (Ta)
−21 °C to +50 °C
Charging
Outside the hazardous area only
Battery swap
Outside the hazardous area only
Ports and accessories in the zone
Connection interfaces must never be used in hazardous areas.
Certified accessories
Tether; digitizer pen or stylus pen (named in the certificate).

Conditions of use

Use only in a controlled environment with reduced pollution; protect from UV light and mechanical impact (impact tested at reduced height); connection interfaces must never be used in hazardous areas; the battery must never be changed, charged or removed in hazardous areas; keep away from strong charge-generating processes; use only Getac battery packs BP2S2P2100S or BP4S1P2100S (IECEx EPS 16.0015X).

Specifications

Full specifications

Certification

IECEx marking
Ex ic op is IIC T4 Gc / Ex ic op is IIIB T130°C Dc
IECEx certificate
IECEx EPS 16.0015X
Protection level (EPL)
Gc / Dc
Dust group
IIIB
Max surface temperature (dust)
130 °C

Device

Type
Rugged tablet, Ex version
Operating system
Not published

Display and camera

Display
8.1-inch

Fleet and support

Manufacturer
Getac Technology Corporation, Taiwan

Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the Getac Technology Corporation website for the full data sheet.

Compare

How it compares

Best in this comparison

Getac T800-Ex compared with its closest alternatives
GetacGetac T800-ExThis tablet
DurabookDurabook R8-EX
BARTECBARTEC ET60/65EX2 Windows
WinmateWinmate M101AD-EX
TypeRugged tablet, Ex versionRugged tablet, Ex versionRugged tablet, Ex versionRugged tablet, Ex version
Screen size8.1-inch8-inch10.1-inch10.1-inch
AvailabilityDiscontinuedCurrentCurrentCurrent
Gas zonesZone 2Zone 2Zone 2Zone 2
Dust zonesZone 22Zone 22Zone 22—
ProtectionIntrinsic safety (Ex ic) with inherently safe optical radiation (op is)Intrinsic safety (Ex ic)Intrinsic safety (Ex ic) with inherently safe optical radiation (op is)Intrinsic safety (Ex ic)
Gas groupIICIICIICIIC
Temperature classT4T4T4T4
CertificationIECExATEXATEX + IECExATEX + IECEx
North America———Class I Division 2
Ambient temperature−21 °C to +50 °C—−20 °C to +55 °C−10 °C to +50 °C
Charging in the Ex areaNot allowedNot allowedNot allowedNot allowed
Operating systemNot publishedWindows 11 ProWindows 11 ProfessionalWindows 11 IoT Enterprise LTSC
Security updates—Supported while kept on a current Windows 11 versionSupported while kept on a current Windows 11 versionUntil October 2034
Weight—880 g (best in this comparison)1200 g1200 g
Display8.1-inch8-inch LCD, DynaVue sunlight-readable, 10-point capacitive10.1-inch Optically bonded capacitive multi-touch, Corning Gorilla Glass, contrast 1000:110.1-inch IPS LED, optical bonding, anti-glare
5G—NoYesYes
Pen / stylus—Optional digitizerPassive stylus included (AI-powered touch control)Capacitive stylus (included)
Replaceable battery—YesYesYes
Hot-swap battery—Optional swappable battery, 5 minute swap (system stays on within 300 s in standby)Yes (true hot swap, minimum 60 seconds)Yes, hot-swappable battery (swap outside hazardous areas per the Ex certificate)
PriceOn requestOn requestOn requestOn request

FAQ

Common questions

Is the Getac T800-Ex certified for Zone 1?

No. It is certified for Zone 2/22 only, so it can be used in Zone 2 but not in Zone 1.

Can the Getac T800-Ex be used in Zone 0?

No. It is not certified for Zone 0. Zone 0 needs equipment with protection level Ga, such as Ex ia intrinsic safety.

What type of explosion protection does the Getac T800-Ex use?

It is intrinsically safe: intrinsic safety (Ex ic) with inherently safe optical radiation (op is). Intrinsic safety limits the electrical and thermal energy in the device below the level that could ignite the surrounding atmosphere.

What does T4 mean for the Getac T800-Ex?

Its surface stays below 135 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.

Can you charge the Getac T800-Ex in a hazardous area?

No. The certificate only allows charging outside the hazardous area.

Which ports and accessories can be used with the Getac T800-Ex in the hazardous area?

Connection interfaces must never be used in hazardous areas.

What operating system does the Getac T800-Ex run?

Not published.

Is the Getac T800-Ex still available?

No. No longer in Getac's range; no end-of-sale notice.

How much does the Getac T800-Ex cost?

Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.