ecom (Pepperl+Fuchs) · Dedicated Ex tablet
ecom Tab-Ex 03 DZ1
- Discontinued
- Zone 1/21
- ATEX
- IECEx
- UKEX
- IIC
- T6
Discontinued. ecom lists it as discontinued. Security patches ended in Q3 2025; hardware service runs to Q4 2027. See the ecom Tab-Ex 05 DZ1
The ecom Tab-Ex 03 DZ1 is a flameproof (Ex d) 8-inch Android tablet from ecom (Pepperl+Fuchs), certified for Zone 1/21 under ATEX, IECEx and UKEX. It runs Android 13. It has been discontinued; the ecom Tab-Ex 05 DZ1 replaces it.
- Certified for
- Zone 1/21
- Protection
- Flameproof enclosure (Ex db) with an intrinsically safe circuit (Ex ia)
- Screen
- 8-inch
- Temperature class
- T6 (≤ 85 °C)
- Ambient temperature
- −20 °C to +55 °C
- Operating system
- Android 13
- Security updates
- Ended Q3 2025
- Weight
- 1100 g
- Price
- On request
Overview
Strengths and limitations
Strengths
- USB-C can be used for data in the zone
- ATEX, IECEx and UKEX certified, with published certificate numbers
- T6 temperature class, the strictest rating
Limitations
- Discontinued; the ecom Tab-Ex 05 DZ1 replaces it
- Security updates ended in Q3 2025
- Battery isn't user-replaceable
- Not certified for Zone 0
Certification
Where you can use it
Gas
- Zone 0not certified.Explosive gas present continuously or for long periods
- Zone 1certified.Explosive gas likely in normal operation
- Zone 2certified.Explosive gas unlikely, and only briefly
Dust
- Zone 20not certified.Combustible dust present continuously or for long periods
- Zone 21certified.Combustible dust likely in normal operation
- Zone 22certified.Combustible dust unlikely, and only briefly
The Ex marking, decoded
Gas atmospheresZones 1 and 2
II2GExdbiaIICT6GbIP64
IIEquipment group- Group II: equipment for surface industries (not mining).
2GATEX category- Category 2 for gas: suitable down to Zone 1.
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
dbProtection type- Flameproof enclosure: the housing is built to contain an ignition inside it and stop the flame reaching the atmosphere outside.
iaProtection type- Intrinsic safety, level "ia": stays safe with two faults. The highest level, required for Zone 0.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T6Temperature class- Surface stays below 85 °C. T6 is the strictest class.
GbProtection level- Equipment protection level Gb (high): suitable for Zone 1 and 2.
IP64Ingress protection- Dust-tight; protected against splashing water.
Dust atmospheresZones 21 and 22
II2DExtbiaIIICT80°CDb
2DATEX category- Category 2 for dust: suitable down to Zone 21.
tbProtection type- Protection by enclosure for dust: the enclosure keeps dust out and its surface stays below the stated temperature.
IIICDust group- Dust group IIIC: conductive dust. The most demanding group; also covers IIIA and IIIB.
T80°CMax surface temperature- Surface stays below 80°C in dust.
DbProtection level- Equipment protection level Db (high): suitable for Zone 21 and 22.
IIExia as above.
Gas atmospheresZones 1 and 2
ExdbiaIICT6GbIP64
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
dbProtection type- Flameproof enclosure: the housing is built to contain an ignition inside it and stop the flame reaching the atmosphere outside.
iaProtection type- Intrinsic safety, level "ia": stays safe with two faults. The highest level, required for Zone 0.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T6Temperature class- Surface stays below 85 °C. T6 is the strictest class.
GbProtection level- Equipment protection level Gb (high): suitable for Zone 1 and 2.
IP64Ingress protection- Dust-tight; protected against splashing water.
Dust atmospheresZones 21 and 22
ExtbiaIIICT80°CDb
tbProtection type- Protection by enclosure for dust: the enclosure keeps dust out and its surface stays below the stated temperature.
IIICDust group- Dust group IIIC: conductive dust. The most demanding group; also covers IIIA and IIIB.
T80°CMax surface temperature- Surface stays below 80°C in dust.
DbProtection level- Equipment protection level Db (high): suitable for Zone 21 and 22.
Exia as above.
Safe use
Rules for the hazardous area
- Ambient temperature (Ta)
- −20 °C to +55 °C
- Charging
- Outside the hazardous area only
- Ports and accessories in the zone
- SIM and microSD are reachable only in non-hazardous areas (flameproof cover). The USB-C port is intrinsically safe and may be used for wired data connections in the hazardous area within its entity parameters (Uo 5.6 V, Io 500 mA, Po 600 mW, Co 1 µF, Lo 1 µH); charging via USB-C only in non-hazardous areas. The S Pen is intrinsically safe and may be used in the hazardous area.
- Certified accessories
- Named in the certificate: Samsung S Pen, ecom type ST T03 X2. No other accessory is named in IECEx EPS 22.0014X.
- IP code in the Ex certificate
- IP64
- Operating temperature
- −20 °C to +55 °C
Conditions of use
Flameproof joints not to be repaired; protect against high-energy impacts and high electrostatic charge; ambient −20 °C to +55 °C; USB-C entity parameters Uo 5.6 V, Io 500 mA (IECEx EPS 22.0014X).
Specifications
Full specifications
Certification
- ATEX marking
- II 2G Ex db ia IIC T6 Gb IP64 / II 2D Ex tb ia IIIC T80°C Db
- ATEX certificate
- EPS 22 ATEX 1 055 X
- IECEx marking
- Ex db ia IIC T6 Gb IP64 / Ex tb ia IIIC T80°C Db
- IECEx certificate
- IECEx EPS 22.0014X (Issue 1, 2025-08-05)
- UKEX certificate
- EPS 22 UKEX 1 055 X (Rev 0)
- North America
- ETL: Class I, Division 1, Groups A,B,C,D T6; Class II, Division 1, Groups E,F,G T85°C; Class III T85°C; Class I, Zone 1, AEx db ia IIC T6 Gb; Zone 21, Group IIIC T85°C; Ta −20 °C to +50 °CUnconfirmed, see note 1
- Protection level (EPL)
- Gb / Db
- Dust group
- IIIC
- Max surface temperature (dust)
- 80 °C
Device
- Type
- Dedicated Ex tablet
- Launched
- 2022Unconfirmed, see note 2
- Operating system
- Android 13
- Edition
- Android 13 (latest firmware)
- OS upgrades
- Android 13 (latest firmware offered)
- Security updates
- Ended Q3 2025
- Processor
- Samsung Exynos 9810 octa-core (4 x 2.7 GHz + 4 x 1.7 GHz)
- Processor architecture
- Arm
- Memory (RAM)
- 4 GB
- Storage
- 64 GB, microSD up to 1024 GB
Field capabilities
- NFC reading
- Built in (NFC)
- Windows desktop software
- Not possible (Android)
Display and camera
- Display
- 8-inch TFT, capacitive multitouch
- Resolution
- 1920 × 1200 (WUXGA)
- Brightness
- 480 nits
- Touch
- Can be operated while wearing gloves
- Rear camera
- 13 MP AF (optional)
- Front camera
- 5 MP
- Video
- UHD 4K at 30 fps
Connectivity
- Network
- 4G LTE (optional) or Wi-Fi only
- Bluetooth
- Bluetooth 5.0
- NFC
- Yes (plus ANT+)
- Satellite positioning
- GPS, Glonass, Beidou, Galileo
- SIM
- 1 x nano-SIM (4FF), optional on DZ1
Physical and power
- Weight
- 1100 g
- Dimensions
- 161.5 × 262.75 × 25.75 mm
- Ingress protection
- IP64 (ATEX/IECEx)
- Battery
- 5050 typical (4900 rated)
- Battery energy
- 18.87
- Battery life
- Up to 11 h
- Replaceable battery
- No
- Ports and expansion
- USB 3.1 Gen 1; microSD; nano-SIM; USB-POGO
Controls & Accessibility
- Glove touch
- Yes
Fleet and support
- Manufacturer
- ecom instruments (Pepperl+Fuchs), Germany
Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the ecom instruments (Pepperl+Fuchs) website for the full data sheet.
Compare
How it compares
Best in this comparison
ecom (Pepperl+Fuchs)ecom Tab-Ex 03 DZ1This tablet | ||||
|---|---|---|---|---|
| Type | Dedicated Ex tablet | Dedicated Ex tablet | Dedicated Ex tablet | Converted tablet |
| Screen size | 8-inch | 8-inch | 8-inch | 8-inch |
| Availability | Discontinued | Current | Current | Current |
| Gas zones | Zone 1, Zone 2 | Zone 1, Zone 2 | Zone 1, Zone 2 | Zone 1, Zone 2 |
| Dust zones | Zone 21, Zone 22 | Zone 21, Zone 22 | Zone 21, Zone 22 | Zone 21, Zone 22 |
| Protection | Flameproof enclosure (Ex db) with an intrinsically safe circuit (Ex ia) | Flameproof enclosure (Ex db) with an intrinsically safe circuit (Ex ia) | Intrinsic safety (Ex ib) | Flameproof enclosure (Ex db) |
| Gas group | IIC | IIC | IIC | IIC |
| Temperature class | T6 (best in this comparison) | T6 (best in this comparison) | T4 | T6 (best in this comparison) |
| Certification | ATEX + IECEx + UKEX | ATEX + IECEx | ATEX + IECEx + UKEX | ATEX + IECEx |
| North America | — | Class I Division 1 | Class I Division 1 | — |
| Ambient temperature | −20 °C to +55 °C | −20 °C to +55 °C | −20 °C to +60 °C | −20 °C to +50 °C |
| Charging in the Ex area | Not allowed | Not allowed | Not allowed | Not allowed |
| Operating system | Android 13 | Android 16 | Android 14 | Android 16 |
| Security updates | Ended Q3 2025 | Until Q1 2032 (best in this comparison) | Until Q1 2027 | Until January 2029 |
| Weight | 1100 g | 1122 g | 890 g (best in this comparison) | 940 g |
| Display | 8-inch TFT, capacitive multitouch | 8-inch TFT, capacitive multitouch, 60 Hz / adaptive up to 120 Hz; Corning Gorilla Glass 3 (DZ1/DZ2), Gorilla Glass 5 (D2) | 8-inch Glove-usable touch display; Corning Gorilla Glass V3 stated on the IS930.M1 page (not on the IS930.1 page) | 8-inch TFT LCD, 120 Hz adaptive; Corning Gorilla Glass 5 |
| 5G | No | Yes | No | Yes |
| Pen / stylus | — | Samsung S Pen included (pressure sensitive), with Tab-Ex S Pen holder | — | S Pen supported (IP68 S Pen in the box on the UK page) |
| Replaceable battery | No | No | No | — |
| Hot-swap battery | — | — | No | — |
| Price | On request | On request | On request | On request |
FAQ
Common questions
Is the ecom Tab-Ex 03 DZ1 certified for Zone 1?
Yes. The ecom Tab-Ex 03 DZ1 is certified for Zone 1/21 with the marking II 2G Ex db ia IIC T6 Gb IP64. Equipment certified for Zone 1 can also be used in Zone 2.
Can the ecom Tab-Ex 03 DZ1 be used in Zone 0?
No. It is not certified for Zone 0. Zone 0 needs equipment with protection level Ga, such as Ex ia intrinsic safety.
What type of explosion protection does the ecom Tab-Ex 03 DZ1 use?
It uses a flameproof enclosure (Ex db), a form of explosion-proof protection. The housing is built to contain an ignition inside it and stop the flame reaching the surrounding atmosphere.
What does T6 mean for the ecom Tab-Ex 03 DZ1?
Its surface stays below 85 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.
Can you charge the ecom Tab-Ex 03 DZ1 in a hazardous area?
No. The certificate only allows charging outside the hazardous area.
Which ports and accessories can be used with the ecom Tab-Ex 03 DZ1 in the hazardous area?
SIM and microSD are reachable only in non-hazardous areas (flameproof cover). The USB-C port is intrinsically safe and may be used for wired data connections in the hazardous area within its entity parameters (Uo 5.6 V, Io 500 mA, Po 600 mW, Co 1 µF, Lo 1 µH); charging via USB-C only in non-hazardous areas. The S Pen is intrinsically safe and may be used in the hazardous area.
What operating system does the ecom Tab-Ex 03 DZ1 run?
Android 13. Security updates ended in Q3 2025.
Is the ecom Tab-Ex 03 DZ1 still available?
No. ecom lists it as discontinued. Security patches ended in Q3 2025; hardware service runs to Q4 2027.
How much does the ecom Tab-Ex 03 DZ1 cost?
Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.
Notes on unconfirmed values
- From the maker's published information; we haven't seen the North American certificate. Return to note 1
- Approximate: the maker doesn't publish a launch date. Based on the certificate date or the maker's announcement. Return to note 2
Sources and verification
Facts last verified on against:
- ecom instruments GmbH / Pepperl+Fuchs SE: ATEX EU-type examination certificate EPS 22 ATEX 1 055 X, Rev 0 (2022-09-07), Tab-Ex 03 DZ1 (ecom CERT-6703)
- ecom instruments GmbH / Pepperl+Fuchs SE: UK type examination certificate EPS 22 UKEX 1 055 X, Rev 0, Tab-Ex 03 DZ1 (ecom CERT-6704)
- IECEx online certificate database (certifying body: Bureau Veritas CPS Germany; SIR certificates: Sira): IECEx EPS 22.0014X issue 1 (2025-08-05), Tab-Ex 03 DZ1
- IECEx online certificate database (certifying body: Bureau Veritas CPS Germany; SIR certificates: Sira): IECEx EPS 21.0033X issue 1 (2025-08-05), Tab-Ex 03 DZ2
- ecom instruments GmbH / Pepperl+Fuchs SE: Tab-Ex 03 DZ1 archive page
- ecom instruments GmbH / Pepperl+Fuchs SE: ecom FAQ: Release Plans of Major Products (OS and security patch plan; last updated 2025-11-18)
- ecom instruments GmbH / Pepperl+Fuchs SE: Tab-Ex 03 DZ2 archive page
Always check the certificate for your exact model before use. Spotted an error? Tell us.