BARTEC · Dedicated Ex tablet
BARTEC Agile X IS
- Discontinued
- Zone 1
- ATEX
- IECEx
- IIC
- T4
- Class I Division 1
Discontinued. BARTEC ended sales in April 2023 and support in April 2026. It names no Zone 1 successor.
The BARTEC Agile X IS is an intrinsically safe (Ex ia) 10.1-inch Windows tablet from BARTEC, certified for Zone 1 under ATEX and IECEx. Its operating system version isn't published. It has been discontinued.
- Certified for
- Zone 1
- Protection
- Intrinsic safety (Ex ia) with inherently safe optical radiation (op is)
- Screen
- 10.1-inch
- Temperature class
- T4 (≤ 135 °C)
- Ambient temperature
- −20 °C to +50 °C
- Operating system
- Not published
- Security updates
- Ended April 2026Unconfirmed, see note 1
- Price
- On request
Overview
Strengths and limitations
Strengths
- Certified for Zone 0, the highest-risk gas zone
- ATEX and IECEx certified, with published certificate numbers
- Also certified for Class I Division 1 in North America
- Optional built-in barcode imager
- Hot-swappable battery for long shifts
Limitations
- No longer in the maker's current range
- T4 temperature class: fine for most gases, but not those that ignite below 135 °C
- No dust zone rating
- Security updates ended in April 2026
- Battery isn't user-replaceable
Certification
Where you can use it
Gas
- Zone 0certified.Explosive gas present continuously or for long periods
- Zone 1certified.Explosive gas likely in normal operation
- Zone 2certified.Explosive gas unlikely, and only briefly
Dust
No dust zones listed in our verified data. Check the certificate.
The Ex marking, decoded
Gas atmospheresZones 0, 1 and 2
II1GExiaop isIICT4Ga
IIEquipment group- Group II: equipment for surface industries (not mining).
1GATEX category- Category 1 for gas: suitable down to Zone 0.
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
iaProtection type- Intrinsic safety, level "ia": stays safe with two faults. The highest level, required for Zone 0.
op isProtection type- Inherently safe optical radiation: light from the camera flash or torch is limited below the level that could ignite the atmosphere.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4Temperature class- Surface stays below 135 °C. T6 is the strictest class.
GaProtection level- Equipment protection level Ga (very high): suitable for Zone 0, 1 and 2.
Gas atmospheresZones 0, 1 and 2
Exiaop isIICT4Ga
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
iaProtection type- Intrinsic safety, level "ia": stays safe with two faults. The highest level, required for Zone 0.
op isProtection type- Inherently safe optical radiation: light from the camera flash or torch is limited below the level that could ignite the atmosphere.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4Temperature class- Surface stays below 135 °C. T6 is the strictest class.
GaProtection level- Equipment protection level Ga (very high): suitable for Zone 0, 1 and 2.
Versions
Marking versions
The certification covers more than one version: ATEX: II 1 G Ex ia op is IIC T4 Ga (Zone 0 types 17-A1B6, 17-A1BB); II 2 G Ex ia op is IIC T4 Gb (Zone 1 types 17-A1B4, 17-A1BA) | IECEx: Ex ia op is IIC T4 Ga / Gb
Safe use
Rules for the hazardous area
- Ambient temperature (Ta)
- −20 °C to +50 °C
- Charging
- Outside the hazardous area only
- Battery swap
- Outside the hazardous area only
- IP code in the Ex certificate
- IP65 (raised to IP65 in IECEx UL 16.0160 issue 1)
- Operating temperature
- −20 °C to +50 °C
Conditions of use
No specific conditions of use on the certificate (IECEx UL 16.0160 has no X suffix). Quick Start Guide Rev C safety rules: do not replace or charge the battery, open the device or dry-wipe or clean it in potentially explosive atmospheres.
Specifications
Full specifications
Certification
- ATEX marking
- II 1G Ex ia op is IIC T4 Ga
- ATEX certificate
- DEMKO 16 ATEX 1803
- IECEx marking
- Ex ia op is IIC T4 Ga
- IECEx certificate
- IECEx UL 16.0160 (Issue 2, 2021-06-30)
- North America
- UL E226123 (Quick Start Guide Rev C): Class I Div 1 Groups A, B, C, D (all types 17-A1B4/B6/BA/BB); Class II Div 1 Groups E, F, G and Class III Div 1 (types 17-A1BA/BB only); USL Class I Zone 0 AEx ia IIC T4 Ga (17-A1B6/BB) / Zone 1 AEx ia IIC T4 Gb (17-A1B4/BA); CNL Ex ia IIC T4 Ga / Gb; −20 °C ≤ Ta ≤ +50 °C
- Protection level (EPL)
- Ga
Device
- Type
- Dedicated Ex tablet
- Launched
- 2016
- Part numbers
- Type 17-A1B*-****/******** (IECEx)
- Operating system
- Not published
- Edition
- Windows 10 IoT Enterprise LTSC 2019, version 1809 (BARTEC image XISLTSC19R01, build 113); earlier units may have had Windows Embedded 8.1
- Security updates
- Ended April 2026Unconfirmed, see note 1
- Processor
- Intel Pentium N3710 quad-core 1.6 GHz (burst 2.56 GHz)
- Processor architecture
- x86
- Memory (RAM)
- 8 GB
- Storage
- 128 GB, microSD up to 32 GB
Field capabilities
- Barcode scanning
- Built in (optional Zebra SE4500 1D/2D scanner)
- RFID
- Built in (optional HF-RFID/NFC reader)
- NFC reading
- Built in (optional)
- Windows desktop software
- Built in (Windows 10 IoT Enterprise, x86)
Display and camera
- Display
- 10.1-inch
- Resolution
- 1920 × 1200
- Brightness
- 700 nits
- Rear camera
- 8 MP AF with LED
- Front camera
- 2 MP
Connectivity
- Wi-Fi
- IEEE 802.11 a/b/g/n/ac
- Bluetooth
- Bluetooth 4.1
- NFC
- Optional HF RFID/NFC reader
Physical and power
- Dimensions
- 290 × 209 × 33 mm
- Ingress protection
- IP65
- Battery
- 4200 mAh
- Battery energy
- 31.1 Wh
- Hot-swap battery
- Yes (optional hot-swappable external battery)
- Replaceable battery
- No
Fleet and support
- Manufacturer
- BARTEC GmbH, Germany
Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the BARTEC GmbH website for the full data sheet.
Compare
How it compares
Best in this comparison
BARTECBARTEC Agile X ISThis tablet | ||||
|---|---|---|---|---|
| Type | Dedicated Ex tablet | Dedicated Ex tablet | Dedicated Ex tablet | Dedicated Ex tablet |
| Screen size | 10.1-inch | 10.1-inch | 10.1-inch | 8-inch |
| Availability | Discontinued | Current | Current | Current |
| Gas zones | Zone 0, Zone 1, Zone 2 (best in this comparison) | Zone 0, Zone 1, Zone 2 (best in this comparison) | Zone 1, Zone 2 | Zone 1, Zone 2 |
| Dust zones | — | Zone 20, Zone 21, Zone 22 | Zone 21, Zone 22 | Zone 21, Zone 22 |
| Protection | Intrinsic safety (Ex ia) with inherently safe optical radiation (op is) | Intrinsic safety (Ex ia) | Intrinsic safety (Ex ib) | Flameproof enclosure (Ex db) with an intrinsically safe circuit (Ex ia) |
| Gas group | IIC | IIC | IIC | IIC |
| Temperature class | T4 | T4 | T4 | T6 (best in this comparison) |
| Certification | ATEX + IECEx | ATEX + IECEx | ATEX + IECEx | ATEX + IECEx |
| North America | Class I Division 1 | Class I Division 1 | Class I Division 1 | Class I Division 1 |
| Ambient temperature | −20 °C to +50 °C | −20 °C to +55 °C | −20 °C to +55 °C | −20 °C to +55 °C |
| Charging in the Ex area | Not allowed | Not allowed | Allowed (see conditions) | Not allowed |
| Operating system | Not published | Windows 11 IoT Enterprise | Windows 11 IoT Enterprise LTSC for Arm64 | Android 16 |
| Security updates | Ended April 2026 | Until October 2034 (best in this comparison) | Until October 2034 (best in this comparison) | Until Q1 2032 |
| Weight | — | 1430 g | 1059 g (best in this comparison) | 1122 g |
| Display | 10.1-inch | 10.1-inch AHVA (IPS-type), 1000:1 contrast, 170 degree viewing angle | 10.1-inch Corning Gorilla Glass V3, usable with gloves | 8-inch TFT, capacitive multitouch, 60 Hz / adaptive up to 120 Hz; Corning Gorilla Glass 3 (DZ1/DZ2), Gorilla Glass 5 (D2) |
| 5G | — | No | Yes | Yes |
| Pen / stylus | — | Stylus supplied (type not stated) | — | Samsung S Pen included (pressure sensitive), with Tab-Ex S Pen holder |
| Replaceable battery | No | No | Yes | No |
| Hot-swap battery | Yes (optional hot-swappable external battery) | — | — | — |
| Price | On request | On request | On request | On request |
FAQ
Common questions
Is the BARTEC Agile X IS certified for Zone 1?
Yes. The BARTEC Agile X IS is certified for Zone 1 with the marking II 1G Ex ia op is IIC T4 Ga. Equipment certified for Zone 1 can also be used in Zone 2.
Can the BARTEC Agile X IS be used in Zone 0?
Yes. It carries protection level Ga, which Zone 0 requires.
What type of explosion protection does the BARTEC Agile X IS use?
It is intrinsically safe: intrinsic safety (Ex ia) with inherently safe optical radiation (op is). Intrinsic safety limits the electrical and thermal energy in the device below the level that could ignite the surrounding atmosphere.
What does T4 mean for the BARTEC Agile X IS?
Its surface stays below 135 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.
Can you charge the BARTEC Agile X IS in a hazardous area?
No. The certificate only allows charging outside the hazardous area.
What operating system does the BARTEC Agile X IS run?
Not published. Security updates ended in April 2026.
Is the BARTEC Agile X IS still available?
No. BARTEC ended sales in April 2023 and support in April 2026. It names no Zone 1 successor.
How much does the BARTEC Agile X IS cost?
Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.
Notes on unconfirmed values
- BARTEC's own end of support for this tablet. Return to note 1
Sources and verification
Facts last verified on against:
- IECEx online certificate database: IECEx UL 16.0160 issue 2 (2021-06-30), Agile X IS
- BARTEC GmbH: Enterprise Mobility Support Portal: Service note - end of life (Agile X IS)
- Rugged PC Review: BARTEC Agile X IS review (specs, launch 2016-11-22)
Always check the certificate for your exact model before use. Spotted an error? Tell us.