Zebra L10 ATEX (Android), front view

Zebra · Rugged tablet, Ex version

Zebra L10 ATEX (Android)

  • Discontinued
  • Zone 2/22
  • ATEX
  • IECEx
  • IIC
  • T6

Discontinued. No longer in Zebra's range. The IECEx certificate for this version was suspended on 6 March 2026; units made before then are unaffected.

The Zebra L10 ATEX (Android) is the hazardous-area version of a Zebra rugged 10.1-inch tablet, certified for Zone 2/22 under ATEX and IECEx. It is an increased-safety (Ex ec) design running Android 10. It has been discontinued.

Certified for
Zone 2/22
Protection
Increased safety (Ex ec)
Screen
10.1-inch
Temperature class
T6 (≤ 85 °C)
Ambient temperature
+5 °C to +35 °C
Operating system
Android 10
Price
On request
Request a price
See how it compares to alternatives

Overview

Strengths and limitations

Strengths

  • ATEX and IECEx certified, with published certificate numbers
  • T6 temperature class, the strictest rating
  • Built-in barcode imager

Limitations

  • No longer in the maker's current range
  • Zone 2 only, so not for Zone 1 areas
  • Dust group IIIB: combustible flyings and non-conductive dust only, not conductive dust
  • Ambient rating tops out at +35 °C
  • Not certified below 5 °C ambient

Certification

Where you can use it

Gas

  • Zone 0not certified.Explosive gas present continuously or for long periods
  • Zone 1not certified.Explosive gas likely in normal operation
  • Zone 2certified.Explosive gas unlikely, and only briefly

Dust

  • Zone 20not certified.Combustible dust present continuously or for long periods
  • Zone 21not certified.Combustible dust likely in normal operation
  • Zone 22certified.Combustible dust unlikely, and only briefly

The Ex marking, decoded

ATEXCertificate TÜV 19 ATEX 8422 X

Gas atmospheresZone 2

II3GExecIICT6Gc

II Equipment group
Group II: equipment for surface industries (not mining).
3G ATEX category
Category 3 for gas: suitable down to Zone 2.
Ex Explosion protected
Certified to the IEC 60079 / EN 60079 series.
ec Protection type
Increased safety, level "ec": extra measures against sparks, arcs and hot surfaces in normal operation. Zone 2 only.
IIC Gas group
Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T6 Temperature class
Surface stays below 85 °C. T6 is the strictest class.
Gc Protection level
Equipment protection level Gc (enhanced): suitable for Zone 2.

Dust atmospheresZone 22

II3DExtcIIIBT85°CDc

3D ATEX category
Category 3 for dust: suitable down to Zone 22.
tc Protection type
Protection by enclosure for dust, level "tc": suitable for Zone 22.
IIIB Dust group
Dust group IIIB: non-conductive dust. Also covers IIIA.
T85°C Max surface temperature
Surface stays below 85°C in dust.
Dc Protection level
Equipment protection level Dc (enhanced): suitable for Zone 22.

IIEx as above.

Safe use

Rules for the hazardous area

Ambient temperature (Ta)
+5 °C to +35 °C
Charging
Outside the hazardous area only
Battery swap
Outside the hazardous area only
Ports and accessories in the zone
All I/O ports (USB, USB-C, RJ-45, HDMI/RS232, audio, micro SD, internal SIM) and DC-in must not be used in the explosive atmosphere.
Certified accessories
Spec sheet: additional 36 Wh ATEX/IECEx standard battery (PN 450173), AC adapter (PN 450154 NA / 450042 EU), long active digitizer pen (PN 440036), short active pen with tether (PN 440037), screen protector (PN 400022). "Other L10 accessories not listed here are not compatible with L10 ATEX models" (no vehicle dock, keyboard or hard handle). The AC adapter is for the safe area only.Unconfirmed, see note 1
IP code in the Ex certificate
IP54 (spec sheet, Ex mode)
Operating temperature
−20 °C to +60 °C (non-hazardous)

Conditions of useUnconfirmed, see note 2

Do not rub plastic parts or the display panel (electrostatic risk). Test level corresponds to low risk of mechanical danger: protect from mechanical danger. All I/O ports and the DC-in connector must not be used in the explosive atmosphere. Use in at least pollution degree 2 (IEC 60664-1). Charge only in the safe area. Hot-swap of the bridge battery only outside the hazardous location.

Specifications

Full specifications

Certification

ATEX marking
II 3G Ex ec IIC T6 Gc / II 3D Ex tc IIIB T85°C Dc
ATEX certificate
TÜV 19 ATEX 8422 X
IECEx marking
Ex ec IIC T6 Gc / Ex tc IIIB T85°C Dc
IECEx certificate
IECEx TUR 19.0052X (issue 0, 2020-02-19, type RTL10B1), Suspended 2026-03-06
Other approvals
Meets IP54 and a 1 m drop to concrete in Ex mode; IP65, 1.8 m drop and -20 to +60 °C in non-hazardous locations (spec sheet)
North America
C1D2 versions of the L10 exist (separate hazardous-location SKU)Unconfirmed, see note 3
Protection level (EPL)
Gc / Dc
Dust group
IIIB
Max surface temperature (dust)
85 °C

Device

Type
Rugged tablet, Ex version
Part numbers
RTL10B1 (type in IECEx TUR 19.0052X); an RTL10B1-O4AA0X0040A6 reseller listing is described as ATEX/IECExUnconfirmed, see note 5
Operating system
Android 10
Edition
Android 10
Processor
Qualcomm Snapdragon 660 (octa-core 2.2 GHz)Unconfirmed, see note 6
Processor architecture
Arm
Memory (RAM)
4 GB

Field capabilities

Barcode scanning
Built in (1D/2D reader on the XPAD only)
Remote expert / video calls
Via app
Windows desktop software
Not possible (Android)

Display and camera

Display
10.1-inch
Resolution
1920 × 1200
Brightness
1000 nits
Touch
Auto-sensing standard, glove and wet touch
Pen / stylus
Active digitizer pen
Rear camera
13 MP
Front camera
5 MP (Android)

Connectivity

Network
Wi-Fi; cellular radio with GPS
Wi-Fi
802.11a/b/g/n/ac/d/h/i/r/k/w
Bluetooth
5.0 Class 2 (BLE)

Physical and power

Dimensions
XSLATE 305.1 × 225.6 × 31; XPAD 305.6 × 278.7 × 32 mm
Ingress protection
IP65 (non-hazardous locations); IP54 in Ex mode
Ruggedness
1 m drop to concrete in Ex mode; 1.8 m outside (spec sheet)
Battery energy
36 Wh
Battery life
Up to 9.8 hours (Android)
Hot-swap battery
Standard bridge battery, 1 minute swap time (outside hazardous locations)
Ports and expansion
2 x USB (2.0 on Android), USB-C, RJ-45, audio, dual nano-SIM, microSDXC

Controls & Accessibility

Glove touch
Yes

Fleet and support

Manufacturer
Zebra Technologies, USA

Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the Zebra Technologies website for the full data sheet.

Compare

How it compares

Best in this comparison

Zebra L10 ATEX (Android) compared with its closest alternatives
ZebraZebra L10 ATEX (Android)This tablet
BARTECBARTEC ET60/65EX2 Android
GetacGetac ZX10-EX G2
AtexxoAtexxo Zone 2 Galaxy Tab Active5 Pro
TypeRugged tablet, Ex versionRugged tablet, Ex versionRugged tablet, Ex versionConverted tablet
Screen size10.1-inch10.1-inch10.1-inch10.1-inch
AvailabilityDiscontinuedCurrentCurrentCurrent
Gas zonesZone 2Zone 2Zone 2Zone 2
Dust zonesZone 22Zone 22Zone 22Zone 22
ProtectionIncreased safety (Ex ec)Intrinsic safety (Ex ic) with inherently safe optical radiation (op is)Intrinsic safety (Ex ic) with inherently safe optical radiation (op is)Increased safety and intrinsic safety (Ex ec ic)
Gas groupIICIICIICIIC
Temperature classT6 (best in this comparison)T4T4T4
CertificationATEX + IECExATEX + IECExATEX + IECExATEX
North America—Class I Division 2——
Ambient temperature+5 °C to +35 °C−20 °C to +55 °C−21 °C to +55 °C—
Charging in the Ex areaNot allowedNot allowedNot allowed—
Operating systemAndroid 10Android 14Android 15Android 16
Security updates—Until December 2031Until December 2029Until May 2033 (best in this comparison)
Weight—1074 g1050 g (best in this comparison)1200 g
Display10.1-inch10.1-inch Optically bonded, multi-mode capacitive touch, Corning Gorilla Glass10.1-inch TFT LCD, LumiBond bonded10.1-inch TFT LCD, 120 Hz adaptive; Corning Gorilla Glass Victus+
5G—YesYesYes
Pen / stylusActive digitizer penStylus supportedDigitizer pen (datasheet); capacitive stylus named in certificateS Pen supported
Replaceable battery—YesYes—
Hot-swap batteryStandard bridge battery, 1 minute swap time (outside hazardous locations)Yes (internal supercapacitor keeps power during battery swaps)——
PriceOn requestOn requestOn requestOn request

FAQ

Common questions

Is the Zebra L10 ATEX (Android) certified for Zone 1?

No. It is certified for Zone 2/22 only, so it can be used in Zone 2 but not in Zone 1.

Can the Zebra L10 ATEX (Android) be used in Zone 0?

No. It is not certified for Zone 0. Zone 0 needs equipment with protection level Ga, such as Ex ia intrinsic safety.

What type of explosion protection does the Zebra L10 ATEX (Android) use?

It combines increased safety (Ex ec) with intrinsic safety (Ex ic), both suited to Zone 2. Increased safety adds measures against sparks and hot surfaces; intrinsic safety limits the energy in the circuits.

What does T6 mean for the Zebra L10 ATEX (Android)?

Its surface stays below 85 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.

Can you charge the Zebra L10 ATEX (Android) in a hazardous area?

No. The certificate only allows charging outside the hazardous area.

Which ports and accessories can be used with the Zebra L10 ATEX (Android) in the hazardous area?

All I/O ports (USB, USB-C, RJ-45, HDMI/RS232, audio, micro SD, internal SIM) and DC-in must not be used in the explosive atmosphere.

What operating system does the Zebra L10 ATEX (Android) run?

Android 10.

Is the Zebra L10 ATEX (Android) still available?

No. No longer in Zebra's range. The IECEx certificate for this version was suspended on 6 March 2026; units made before then are unaffected.

How much does the Zebra L10 ATEX (Android) cost?

Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.

Notes on unconfirmed values

  1. Not checked against the certificate for this exact model.
  2. From the IECEx certificate for the Android version (suspended in March 2026); the Windows version's certificate isn't published.
  3. From the maker's published information; we haven't seen the North American certificate.
  4. Approximate: the maker doesn't publish a launch date. Based on the certificate date or the maker's announcement.
  5. Order codes from a certificate or distributor; confirm them with the maker when ordering.
  6. From a single or secondary source; the maker doesn't state it for this model.

Sources and verification

Facts last verified on against:

Always check the certificate for your exact model before use. Spotted an error? Tell us.