i.safe MOBILE · Dedicated Ex tablet
i.safe MOBILE IS930.2
- Zone 2/22
- ATEX
- IECEx
- IIC
- T4
- Class I Division 2
The i.safe MOBILE IS930.2 is an intrinsically safe (Ex ic) 8-inch Android tablet from i.safe MOBILE, certified for Zone 2/22 under ATEX and IECEx. It runs Android 14.
- Certified for
- Zone 2/22
- Protection
- Intrinsic safety (Ex ic)
- Screen
- 8-inch
- Temperature class
- T4 (≤ 135 °C)
- Ambient temperature
- −20 °C to +60 °C
- Operating system
- Android 14
- Security updates
- Until Q1 2027
- Weight
- 890 g
- Price
- On request
Overview
Strengths and limitations
Strengths
- ATEX and IECEx certified, with published certificate numbers
- Also certified for Class I Division 2 in North America
- Certified for ambient temperatures up to +60 °C
Limitations
- Zone 2 only, so not for Zone 1 areas
- T4 temperature class: fine for most gases, but not those that ignite below 135 °C
- Security updates end in Q1 2027
- Battery isn't user-replaceable
Certification
Where you can use it
Gas
- Zone 0not certified.Explosive gas present continuously or for long periods
- Zone 1not certified.Explosive gas likely in normal operation
- Zone 2certified.Explosive gas unlikely, and only briefly
Dust
- Zone 20not certified.Combustible dust present continuously or for long periods
- Zone 21not certified.Combustible dust likely in normal operation
- Zone 22certified.Combustible dust unlikely, and only briefly
The Ex marking, decoded
Gas atmospheresZone 2
II3GExicIICT4GcIP64
IIEquipment group- Group II: equipment for surface industries (not mining).
3GATEX category- Category 3 for gas: suitable down to Zone 2.
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
icProtection type- Intrinsic safety, level "ic": safe in normal operation. Zone 2 only.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4Temperature class- Surface stays below 135 °C. T6 is the strictest class.
GcProtection level- Equipment protection level Gc (enhanced): suitable for Zone 2.
IP64Ingress protection- Dust-tight; protected against splashing water.
Dust atmospheresZone 22
II3DExicIIICT135°CDcIP64
3DATEX category- Category 3 for dust: suitable down to Zone 22.
IIICDust group- Dust group IIIC: conductive dust. The most demanding group; also covers IIIA and IIIB.
T135°CMax surface temperature- Surface stays below 135°C in dust.
DcProtection level- Equipment protection level Dc (enhanced): suitable for Zone 22.
IIExicIP64 as above.
Gas atmospheresZone 2
ExicIICT4GcIP64
ExExplosion protected- Certified to the IEC 60079 / EN 60079 series.
icProtection type- Intrinsic safety, level "ic": safe in normal operation. Zone 2 only.
IICGas group- Gas group IIC, e.g. hydrogen and acetylene. The most demanding group; also covers IIA and IIB.
T4Temperature class- Surface stays below 135 °C. T6 is the strictest class.
GcProtection level- Equipment protection level Gc (enhanced): suitable for Zone 2.
IP64Ingress protection- Dust-tight; protected against splashing water.
Dust atmospheresZone 22
ExicIIICT135°CDcIP64
IIICDust group- Dust group IIIC: conductive dust. The most demanding group; also covers IIIA and IIIB.
T135°CMax surface temperature- Surface stays below 135°C in dust.
DcProtection level- Equipment protection level Dc (enhanced): suitable for Zone 22.
ExicIP64 as above.
Safe use
Rules for the hazardous area
- Ambient temperature (Ta)
- −20 °C to +60 °C
- Charging
- Outside the hazardous area only
- Battery swap
- Outside the hazardous area only
- Ports and accessories in the zone
- Opening interface or connector covers in an Ex area is not permitted; physical connections to other equipment only outside Ex areas.
- Certified accessories
- As IS-930.1: IS-DS930.1 dock, IS-MC930.1 multi charger, PROTECTOR cables, leather case and straps, vehicle mount (all charging/cable items outside Ex areas).Unconfirmed, see note 1
- IP code in the Ex certificate
- IP64
- Operating temperature
- −20 °C to +60 °C
Conditions of use
IECEx X conditions: battery may be charged outside explosion hazardous areas only; protect against permanent UV light and high electrostatic charge processes; ambient −20 °C to +60 °C. Safety instructions: only zones 2 or 22; all interface covers closed in Ex areas; charge only outside Ex areas at +5 to +35 °C; battery not interchangeable.
Specifications
Full specifications
Certification
- ATEX marking
- II 3G Ex ic IIC T4 Gc IP64 / II 3D Ex ic IIIC T135°C Dc IP64
- ATEX certificate
- EPS 19 ATEX 1 072 X
- IECEx marking
- Ex ic IIC T4 Gc IP64 / Ex ic IIIC T135°C Dc IP64
- IECEx certificate
- IECEx EPS 19.0035X (Issue 0, 2020-01-31)
- Other approvals
- EAC, KCs, INMETRO, IA South Africa
- North America
- NEC 500: Class I Div 2 Groups A, B, C, D T4; Class II Div 2 Groups F, G T135°C; Class III Div 2 (CSA 20CA70220244)
- Protection level (EPL)
- Gc / Dc
- Dust group
- IIIC
- Max surface temperature (dust)
- 135 °C
Device
- Type
- Dedicated Ex tablet
- Launched
- 2020Unconfirmed, see note 2
- Part numbers
- Model M93A01 (DoC)
- Operating system
- Android 14
- Edition
- Android 14
- OS at launch
- Android 9Unconfirmed, see note 3
- Security updates
- Until Q1 2027
- Processor
- Qualcomm Snapdragon SDM660 octa-core
- Processor architecture
- Arm
- Memory (RAM)
- 4 GB
- Storage
- 64 GB, microSD up to 512 GB
Field capabilities
- Push-to-talk
- Via app (PTT/PoC app on a programmable key; no PTT button accessory listed for IS930)
- Emergency / SOS
- Built in (dedicated red SOS key)
- Lone worker
- Via app (LWP ready: third-party application required, per maker page)
- Barcode scanning
- Via app (camera-based; no dedicated scan engine listed)
- NFC reading
- Built in (NFC)
- 3D scanning / LiDAR
- Not possible (no depth sensor listed)
- Remote expert / video calls
- Via app (front and rear cameras, Wi-Fi/LTE; third-party app)
- Windows desktop software
- Not possible (Android)
Display and camera
- Display
- 8-inch Glove-usable touch display; Corning Gorilla Glass V3 stated on the IS930.M1 page (not on the IS930.1 page)
- Touch
- Usable with gloves (maker); wet-touch not stated
- Rear camera
- 13 MP autofocus
- Front camera
- 5 MP fixed focus
Connectivity
- Network
- 4G LTE (no 5G)
- Wi-Fi
- Wi-Fi 5 (802.11 a/b/g/n/ac/e/k/r/h) with hotspot
- Bluetooth
- Bluetooth 5
- NFC
- Yes
- Satellite positioning
- GPS, A-GPS, Glonass, Beidou (Galileo added on IS930.M1 page)
- SIM
- Micro-SIM
Physical and power
- Weight
- 890 g
- Dimensions
- 237 × 156 × 22 mm
- Ingress protection
- IP68
- Ruggedness
- MIL-STD-810H
- Battery
- 8160Unconfirmed, see note 3
- Battery energy
- 30.2Unconfirmed, see note 4
- Hot-swap battery
- NoUnconfirmed, see note 3
- Replaceable battery
- No
- Ports and expansion
- USB-C; 24-pin docking interface; magnetic charger port; earphone jack; microSD slot; micro-SIM
- Docking
- Office dock IS-DS930.1 (RJ45, 3 x USB); IS-MC930.1 six-bay multi charger; vehicle mount
- Keyboard
- No (slate)
Controls & Accessibility
- Keys
- SOS key (red); two freely programmable keys
- Push-to-talk key
- No
- Glove touch
- Yes
Fleet and support
- Manufacturer
- i.safe MOBILE GmbH, Germany
Only specifications we could check are listed. A numbered marker next to a value means it is unconfirmed: it comes from a single or secondary source, or sources disagree. The matching note at the foot of the page explains each one. See the i.safe MOBILE GmbH website for the full data sheet.
Compare
How it compares
Best in this comparison
i.safe MOBILEi.safe MOBILE IS930.2This tablet | ||||
|---|---|---|---|---|
| Type | Dedicated Ex tablet | Dedicated Ex tablet | Dedicated Ex tablet | Rugged tablet, Ex version |
| Screen size | 8-inch | 8-inch | 7-inch | 8-inch |
| Availability | Current | Current | Current | Current |
| Gas zones | Zone 2 | Zone 2 | Zone 2 | Zone 2 |
| Dust zones | Zone 22 | Zone 22 | Zone 22 | Zone 22 |
| Protection | Intrinsic safety (Ex ic) | Intrinsic safety (Ex ic) | Increased safety and intrinsic safety (Ex ec ic) | Intrinsic safety (Ex ic) with inherently safe optical radiation (op is) |
| Gas group | IIC | IIC | IIC | IIC |
| Temperature class | T4 | T5 (best in this comparison) | T5 (best in this comparison) | T4 |
| Certification | ATEX + IECEx | ATEX + IECEx | ATEX + IECEx | ATEX + IECEx |
| North America | Class I Division 2 | Class I Division 2 | — | — |
| Ambient temperature | −20 °C to +60 °C | −20 °C to +55 °C | −10 °C to +50 °C | −21 °C to +55 °C |
| Charging in the Ex area | Not allowed | Not allowed | Not allowed | Not allowed |
| Operating system | Android 14 | Android 16 | Android (version not published) | Android 15 |
| Security updates | Until Q1 2027 | Until Q1 2032 (best in this comparison) | — | Until February 2029 |
| Weight | 890 g | 595 g (best in this comparison) | 800 g | 780 g |
| Display | 8-inch Glove-usable touch display; Corning Gorilla Glass V3 stated on the IS930.M1 page (not on the IS930.1 page) | 8-inch TFT, capacitive multitouch, 60 Hz / adaptive up to 120 Hz; Corning Gorilla Glass 3 (DZ1/DZ2), Gorilla Glass 5 (D2) | 7-inch Colour TFT IPS, anti-glare, high-impact polycarbonate touchscreen | 8-inch TFT LCD wide viewing angle; Ex model has 0.6 mm thicker glass per ZX80W-EX press release |
| 5G | No | Yes | No | Yes |
| Pen / stylus | — | Samsung S Pen included (pressure sensitive), with Tab-Ex S Pen holder | Signature capture on the touchscreen | Digitizer pen |
| Replaceable battery | No | No | — | Yes |
| Hot-swap battery | No | — | — | Internal battery plus optional swappable 4990 mAh battery; hot-swap not stated for the Ex datasheet |
| Price | On request | On request | On request | On request |
FAQ
Common questions
Is the i.safe MOBILE IS930.2 certified for Zone 1?
No. It is certified for Zone 2/22 only, so it can be used in Zone 2 but not in Zone 1.
Can the i.safe MOBILE IS930.2 be used in Zone 0?
No. It is not certified for Zone 0. Zone 0 needs equipment with protection level Ga, such as Ex ia intrinsic safety.
What type of explosion protection does the i.safe MOBILE IS930.2 use?
It is intrinsically safe: intrinsic safety (Ex ic). Intrinsic safety limits the electrical and thermal energy in the device below the level that could ignite the surrounding atmosphere.
What does T4 mean for the i.safe MOBILE IS930.2?
Its surface stays below 135 °C, so it is suitable for gases that only ignite above that temperature. Check the ignition temperature of the substances on your site.
Can you charge the i.safe MOBILE IS930.2 in a hazardous area?
No. The certificate only allows charging outside the hazardous area.
Which ports and accessories can be used with the i.safe MOBILE IS930.2 in the hazardous area?
Opening interface or connector covers in an Ex area is not permitted; physical connections to other equipment only outside Ex areas.
What operating system does the i.safe MOBILE IS930.2 run?
Android 14. Security updates until Q1 2027.
How much does the i.safe MOBILE IS930.2 cost?
Prices for certified hazardous-area tablets depend on volume, configuration and region, so they are on request. Contact us for a price.
Notes on unconfirmed values
- Not checked against the certificate for this exact model. Return to note 1
- Approximate: the maker doesn't publish a launch date. Based on the certificate date or the maker's announcement. Return to note 2
- From a single or secondary source; the maker doesn't state it for this model. Return to note 3
- Calculated from the maker's battery capacity and voltage; the maker doesn't state watt-hours. Return to note 4
Sources and verification
Facts last verified on against:
- IECEx online certificate database (certifying body: Bureau Veritas CPS Germany): IECEx EPS 19.0035X issue 0 (2020-01-31), IS930.2
- IECEx online certificate database (certifying body: Bureau Veritas CPS Germany): IECEx EPS 19.0034X issue 0 (2019-12-20), IS930.1
- i.safe MOBILE GmbH: EU Declaration of Conformity 1041CC06REV00 IS930.2 (EPS 19 ATEX 1 072 X)
- i.safe MOBILE GmbH: IS930.2 Safety Instructions 1041MM11REV05
- i.safe MOBILE GmbH: IS930.1 Safety Instructions 1030MM11REV05
- i.safe MOBILE GmbH: IS930.2 product page (Zone 2/22)
- i.safe MOBILE GmbH: IS930.1 product page (Zone 1/21)
- i.safe MOBILE GmbH: IS930.M1 mining product page
- i.safe MOBILE GmbH: Security updates page (Security Patch Updates table), read 2026-10-25
Always check the certificate for your exact model before use. Spotted an error? Tell us.